CSPE 45 mils 3 Ply Liner
| Test | ASTM Test Method | Minimum Requirement |
| Thickness (Average) | D751 | 45 mils(1.14mm) total* |
| 11 mils (0.28mm) over scrim | ||
| Tensile Strength at break (two directions, parallel and perpendicular to reinforcing scrim) | D751 Grab method | 250 lbs |
| 113kgf | ||
| Elongation at Break | D751 Method A Procedure 1 | 350 psi |
| 2413 kPa | ||
| Puncture Resistance | FTMS 101B Method 2031 | 200 lbs |
| 91 kgf | ||
| Bonded Seam Strength | D751 Modified (12 in/min) | 225 lbs |
| 102 kgf | ||
| Ply Adhesion | D413 Machine Method, Type A (12 in/min) | 8 lbs |
| 3.6 kgf | ||
| Ozone Resistance | D1149, 3mm Bent Loop, 100 pphm, 40°, 7 days | No Cracking |
| Low Temperature Resistance | D2136, 1/8 in Mandrel, 4 hrs (-40°C) | 1% Max |
| UV Resistance | EMMAQUA Accelerated Weathering to E838 for 3 million Langleys | No Surface Cracking or Crazing |
* The information contained herein is provided for reference purposes only and is not intended as a warranty of guarantee. Final determination of suitability for use contemplated is the sole responsibility of the user. Jaylon is not responsible if specifications are incorrect or product differentiates.